Skip to content

Add TOLL-8 footprint - #777

Draft
Abse2001 wants to merge 1 commit into
tscircuit:mainfrom
Abse2001:agent/add-toll8-c2979263
Draft

Add TOLL-8 footprint#777
Abse2001 wants to merge 1 commit into
tscircuit:mainfrom
Abse2001:agent/add-toll8-c2979263

Conversation

@Abse2001

@Abse2001 Abse2001 commented Aug 7, 2026

Copy link
Copy Markdown
Contributor

Summary

  • add an explicit toll8 footprint variant
  • model its eight leads, drain bridge, and large drain pad
  • add a C2979263 regression test and SVG snapshot

Motivation

HYG015N10NS1TA (JLCPCB C2979263) uses the distinct TOLL-8 copper topology. Treating the large drain land as an offset thermal pad in a two-sided IC family reached only 86.22% copper IoU.

Implementation

The first TOLL-8 variant encodes the verified land pattern directly. It deliberately avoids speculative controls for each lead, bridge, and drain dimension until additional real TOLL variants require them.

Validation

  • bun test tests/toll.test.ts: 1 passed
  • bun run build
  • C2979263 copper IoU: 99.997%
  • new SVG snapshot for the real TOLL-8 footprint

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment